Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Fluoresc ; 33(2): 565-574, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36454426

RESUMO

The fluorescence-based portable device for the determination of lead (Pb2+) and formalin (FA) in food samples by using Nitrogen-doped carbon dots (N-CDs) as a fluorescence probe was developed. The proposed approach, Pb2+, and FA were determined based on the photo-induced electron transfer (PET) mechanism and the silver mirror reaction. The fluorescence intensity of the N-CDs decreased with the increase of Pb2+ concentration and increased with the increasing FA concentration. The fluorescence intensity of N-CDs after the reactions were measured by a filter-free fluorometer platform using a commercial camera module and a Raspberry Pi, a compact computer, as a detector and processor. The experimental results were obtained using control samples with known Pb2+ and FA concentrations in the 0.01-10 mg L- 1 and 25-150 mg L- 1, respectively. The proposed approach is simple, low-cost, and accurate for the on-site monitoring of Pb2+ and FA in various food samples. Of utmost importance, the proposed approach is expected to be a pioneering model for the future development of other analytes with a broad range of practical applications.


Assuntos
Pontos Quânticos , Carbono , Nitrogênio , Chumbo , Corantes Fluorescentes , Espectrometria de Fluorescência/métodos
2.
Anal Chem ; 94(40): 13785-13794, 2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36153983

RESUMO

Vanadium-doped porous Co3O4 (V-porous Co3O4) was synthesized via a simple soft-templating method and used as a superior peroxidase mimic for the simultaneous colorimetric determination of glucose and total cholesterol (TC) in whole blood samples on a two-dimensional microfluidic paper-based analytical device (2D-µPAD). The large surface area and the presence of two metals in V-porous Co3O4 contributed to its excellent catalytic activity toward 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) (ABTS) and 3,3',5,5'- tetramethylbenzidine (TMB) with Michaelis-Menten constants (KM) of 0.1301 and 0.0141 mM, respectively. The 2D-µPAD was fabricated using simple wax screen-printing and cutting techniques. The colorimetric reactions of both glucose and TC on 2D-µPAD were simultaneously performed by adding a single drop of a whole blood sample on the sample zone made of the LF1 membrane. After the enzymatic reactions, the generated hydrogen peroxide (H2O2) was oxidized by V-porous Co3O4 to produce hydroxy radicals (•OH), inducing ABTS and TMB to generate colored products. The generated H2O2 was proportional to the intensities of the green and blue products of the glucose and TC systems, respectively. The developed 2D-µPAD required a short analysis time (∼5 min) with small volumes of samples (15 µL of whole blood) whereby no sample preparation was needed. Owing to several advantages including simplicity, low cost, long-term stability, and simultaneous readout, the novel V-porous Co3O4 coupled with 2D-µPAD proved to be promising for practical uses as a pioneering portable device for the determination of glucose, TC, and other important biomarkers without the need of technical supports.


Assuntos
Glucose , Peróxido de Hidrogênio , Benzidinas , Benzotiazóis , Colesterol , Cobalto , Colorimetria/métodos , Glucose/análise , Peróxido de Hidrogênio/análise , Óxidos , Peroxidase , Porosidade , Ácidos Sulfônicos , Vanádio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...